Fuji/Carestream Cassettes & Image Plates

CR Cassettes & Image Plates

Fujifilm Imaging Plates (IPs) are the result of years of research and continuous improvement. Fujifilm's IP design employs an extremely efficient image recording medium based on a high-emission, photostimulable phosphor, which accurately detects and stores X-ray energy. Fujifilm's phosphor composition offers high sensitivity, high sharpness, and low noise. We purchase used CR Cassettes.

AMI Medical Imaging

Fujifilm Type CC Cassettes

Fujifilm CR cassettes are available in most common sizes as well as extended lengths for long leg and scoliosis exams. The cassettes are of a lightweight and rugged design to safely house and protect Fuji's advanced flexible imaging plates. Cassettes and IPs are sold separately. We purchase used CR Cassettes. The XL-2's 50-micron capability utilizes Type-CH 18 x 24 cm cassettes and single-sided HR imaging plates.

Fujifilm Type CC Cassette and Image Plate (IPS) Sizes
14" x 17" (35 x 43 cm) 18 x 24 cm
14" x 14" (35 x 35 cm) 24 x 30 cm
10" x 12" 15 x 30 cm

Kodak or Carestream DirectView CR and Kodak ACR Cassettes, Image Plates, and Gridded Kodak CR Cassettes

Offering a complete line of Kodak DirectView ACR Cassettes, including CR 500 cassettes, CR 850/950 single-cassettes. We purchase used CR Cassettes.

Kodak or Carestream DirectView CR Cassettes for CR 800 and CR 900 Series

AMI Medical Imaging
Kodak DirectView CR Cassette / GP Sizes
35 x 43 cm Kodak 18 x 24 cm
35 x 35 cm 15 x 30 cm *
24 x 30 cm
* Available for CR 850/950 Systems only
Kodak DirectView CR Cassette / HR Sizes
24 x 30 cm 18 x 24 cm
Kodak DirectView CR 500 Cassette / GP Sizes
35 x 43 cm 18 x 24 cm
35 x 35 cm 15 x 30 cm *
24 x 30 cm
Kodak ACR Cassettes Storage Phosphor Cassette for Kodak ACR Systems
35 x 43 cm 20 x 25 cm
24 x 30 cm
AMI Medical Imaging

FCR One Shot Phantom

FCR One Shot Phantom enables a system-wide quality analysis by incorporating eight performance tests into a single exposure. The Fuji FCR 1 Shot Phantom provides a valuable evaluation of the Imaging Plate, CR Image Reader, Exposure Room, Hard Copy Printer, and Imaging Workstations. Only minutes to expose and interpret, the FCR 1 Shot Phantom has no moving parts and requires no electrical power. A comprehensive QA system, complete with phantom, manual, and reporting forms is incorporated into a single package.

Contact AMI Medical Imaging for more information at (814)289-6214.

Quality Analysis Programs FCR One Phantom Plus

FCR One Shot Phantom Plus is specifically for use with Fujifilm CR and DR systems as well as the QC workstations. The FCR 1 Shot Phantom Plus is an advanced quality analysis system incorporating extensive test parameters into an automated program. Visual and automatic calculations as well as simple Pass/Fail programs can be easily performed through the simple step-by-step user interface of the Flash IIP console. Default values for each test are pre-set in the software however the user can re-set those values in accordance to reference or local or federal mandate.

AMI Medical Imaging

Storage Phosphor Image Plate Cleaning Kit

Do your CR screens and imaging plates have black spots that cause minus density specs on your images or smudges from hand lotions, topical medications, food, etc? Our screen cleaner will not perform miracles, however, you can expect it to clean spots and smudges you may have thought impossible and possibly save you the expense of replacing CR image plates and screens.

AMI Medical Imaging

Image Plate and Screen Cleaning Kit Contains:

  • 16oz Screen Cleaning Solution
  • 2 Lint Free Cleaning Cloths

Storage phosphor screens and imaging plates should be cleaned every 200 exposures, every 30 days or when artifacts appear. Under normal use conditions, storage phosphor screens will eventually show wear.

This may occur from abrasion of the protective overcoat or inadvertent physical damage to the surface.

Certain chemical solutions, hand lotions, topical medications, food, etc, may also damage the screens. Screen wear can result in artifacts on radiographs.

CAUTION: Isopropyl (rubbing alcohol) is not recommended for cleaning storage screens.

Image Plate and Screen Cleaning Kit Contains:

  • 16oz Screen Cleaning Solution
  • 2 Lint Free Cleaning Cloths

Storage phosphor screens and imaging plates should be cleaned every 200 exposures, every 30 days or when artifacts appear. Under normal use conditions, storage phosphor screens will eventually show wear.  This may occur from abrasion of the protective overcoat or inadvertent physical damage to the surface.

Certain chemical solutions, hand lotions, topical medications, food, etc, may also damage the screens. Screen wear can result in artifacts on radiographs. CAUTION: Isopropyl (rubbing alcohol) is not recommended for cleaning storage screens.

To Clean:

  • Gently clean only the soiled area on the storage phosphor screen. Never spray the cleaning solution directly on the screen.
  • Then, clean the whole screen with a moistened soft cloth with a screen cleaner.
  • Dry the phosphor screen with a soft dry lint-free cloth supplied.

CR Cassettes and screens contain lead and other chemicals regulated due to environmental considerations. For disposal or recycling information call AMI Medical Imaging at
(814)289-6214
.

CR IMAGE PLATE CLEANING KIT Product # 260811